Rectifier and Regenerative Units
Intelligent Search for Components
Search according to your product code, category of product or manufacturer and you will find your requested component fast and easy. Should you nevertheless not be able to trace the part you are looking for – our experts will gladly help you Tel: +49 8196 9000-110.
Supply and regenerative units in the field of driving automation
Supply and regenerative units in the field of driving automation are commonly build in together with converters, frequency converters operating machinery or electric motors
With the help of supply units a variable number of frequency converters can be provided with the necessary power. Apart from able to be used as singular modules a joined assembly is possible. Due to the contructive nature of regenerative units excess power can be fed back into the pending power supply and help to cut down costs and also minimize the usage of energy slowing down the generators attached.
Repair
EICHLER is specialized in servicing supply and regenerative units of numerous manufacturers. All modules are specifically repaired down to the individual component according to the actual damage recorded. Final endurance tests ensure the functionability.
Sale
EICHLER offers a large variety of current and discontinued types of supply and regenerative units. Every item is fully tested and fitted with a 24 months warranty.
Product Overview
Should you not have the specific item number at hand kindly refer to the product overview showing you our reference on supply and regenerative units.
Product Overview on supply and regenerative units
Following you will see an overview of all supply and regenerative unitsavailable online. For further details referring to the individual item please klick on the article code accordingly. Should you nevertheless not be able to trace the item requested kindly use the intelligent search for components or simply give us a call: +49 8196 9000-110
Article Name | Article Description | Scope | Article Group Name | Manufacturer |
---|---|---|---|---|
6SE7137-0EG80-2BA0 | SIMOVERT MASTERDRIVES VECTOR CONTROL EIN-/RUECKSPEISE-EINHEIT SELBSTGEFUEHRT U. GEPULST (AFE) SCHRANKGERAET, SCHUTZART IP20 3 AC 380-480V, 50/60HZ BEMESSUNGSEINGANGSSTROM: 655A TYPENLEISTUNG: 443KW BEI COS PHI = 1 UND UN = 400V | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SE7137-0EK62-5BA0 | SIMOVERT MASTERDRIVES VECTOR CONTROL EINSPEISE-RUECKSPEISE-EINHEIT SELBSTGEFUEHRT U. GEPULST (AFE) SCHRANKGERAET, SCHUTZART IP20 3 AC 380-480V, 50/60HZ, 690A TYPENLEISTUNG: 400KW | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SE7138-6EG80-2BA0 | SIMOVERT MASTERDRIVES VECTOR CONTROL EIN-/RUECKSPEISE-EINHEIT SELBSTGEFUEHRT U. GEPULST (AFE) SCHRANKGERAET, SCHUTZART IP20 3 AC 380-480V, 50/60HZ BEMESSUNGSEINGANGSSTROM: 817A TYPENLEISTUNG: 550KW BEI COS PHI = 1 UND UN = 400V | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SE7138-6EK62-5BA0 | SIMOVERT MASTERDRIVES VECTOR CONTROL EINSPEISE-RUECKSPEISE-EINHEIT SELBSTGEFUEHRT U. GEPULST (AFE) SCHRANKGERAET, SCHUTZART IP20 3 AC 380-480V, 50/60HZ, 860A TYPENLEISTUNG: 500KW | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SE7138-6FG80-2BA0 | SIMOVERT MASTERDRIVES VECTOR CONTROL EIN-/RUECKSPEISE-EINHEIT SELBSTGEFUEHRT U. GEPULST (AFE) SCHRANKGERAET, SCHUTZART IP20 3 AC 500-575V, 50/60HZ BEMESSUNGSEINGANGSSTROM: 817A TYPENLEISTUNG: 692KW BEI COS PHI = 1 UND UN = 500V | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SE7138-6FK62-5BA0 | SIMOVERT MASTERDRIVES VECTOR CONTROL EINSPEISE-RUECKSPEISE-EINHEIT SELBSTGEFUEHRT U. GEPULST (AFE) SCHRANKGERAET, SCHUTZART IP20 3 AC 500-575V, 50/60HZ, 860A TYPENLEISTUNG: 630KW | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SE7138-6HG80-2BA0 | SIMOVERT MASTERDRIVES VECTOR CONTROL EIN-/RUECKSPEISE-EINHEIT SELBSTGEFUEHRT U. GEPULST (AFE) SCHRANKGERAET, SCHUTZART IP20 3 AC 600-690V, 50/60HZ BEMESSUNGSEINGANGSSTROM: 774A TYPENLEISTUNG: 906KW BEI COS PHI = 1 UND UN = 690V | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SE7138-6HK62-5BA0 | SIMOVERT MASTERDRIVES VECTOR CONTROL EINSPEISE-RUECKSPEISE-EINHEIT SELBSTGEFUEHRT U. GEPULST (AFE) SCHRANKGERAET, SCHUTZART IP20 3 AC 600-690V, 50/60HZ, 860A TYPENLEISTUNG: 800KW | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SE7141-1EL62-5BA0 | SIMOVERT MASTERDRIVES VECTOR CONTROL EINSPEISE-RUECKSPEISE-EINHEIT SELBSTGEFUEHRT U. GEPULST (AFE) SCHRANKGERAET, SCHUTZART IP20 3 AC 380-480V, 50/60HZ, 1100A TYPENLEISTUNG: 630KW | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SE7141-1FH80-2BA0 | SIMOVERT MASTERDRIVES VECTOR CONTROL EIN-/RUECKSPEISE-EINHEIT SELBSTGEFUEHRT U. GEPULST (AFE) SCHRANKGERAET, SCHUTZART IP20 3 AC 500-575V, 50/60HZ BEMESSUNGSEINGANGSSTROM: 1026A TYPENLEISTUNG: 869KW BEI COS PHI = 1 UND UN = 500V | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SE7141-1FM62-5BA0 | SIMOVERT MASTERDRIVES VECTOR CONTROL EINSPEISE-RUECKSPEISE-EINHEIT SELBSTGEFUEHRT U. GEPULST (AFE) SCHRANKGERAET, SCHUTZART IP20 3 AC 500-575V, 50/60HZ, 1080A TYPENLEISTUNG: 800KW | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SE7141-1HH80-2BA0 | SIMOVERT MASTERDRIVES VECTOR CONTROL EIN-/RUECKSPEISE-EINHEIT SELBSTGEFUEHRT U. GEPULST (AFE) SCHRANKGERAET, SCHUTZART IP20 3 AC 600-690V, 50/60HZ BEMESSUNGSEINGANGSSTROM: 972A TYPENLEISTUNG: 1138KW BEI COS PHI = 1 UND UN = 690V | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SE7141-1HM62-5BA0 | SIMOVERT MASTERDRIVES VECTOR CONTROL EINSPEISE-RUECKSPEISE-EINHEIT SELBSTGEFUEHRT U. GEPULST (AFE) SCHRANKGERAET, SCHUTZART IP20 3 AC 600-690V, 50/60HZ, 1080A TYPENLEISTUNG: 1000KW | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SE7141-2FH80-2BA0 | SIMOVERT MASTERDRIVES VECTOR CONTROL EIN-/RUECKSPEISE-EINHEIT SELBSTGEFUEHRT U. GEPULST (AFE) SCHRANKGERAET, SCHUTZART IP20 3 AC 500-575V, 50/60HZ BEMESSUNGSEINGANGSSTROM: 1168A TYPENLEISTUNG: 989KW BEI COS PHI = 1 UND UN = 500V | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SE7141-2FM62-5BA0 | SIMOVERT MASTERDRIVES VECTOR CONTROL EINSPEISE-RUECKSPEISE-EINHEIT SELBSTGEFUEHRT U. GEPULST (AFE) SCHRANKGERAET, SCHUTZART IP20 3 AC 500-575V, 50/60HZ, 1230A TYPENLEISTUNG: 900KW | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SE7141-2HH80-2BA0 | SIMOVERT MASTERDRIVES VECTOR CONTROL EIN-/RUECKSPEISE-EINHEIT SELBSTGEFUEHRT U. GEPULST (AFE) SCHRANKGERAET, SCHUTZART IP20 3 AC 600-690V, 50/60HZ BEMESSUNGSEINGANGSSTROM: 1107A TYPENLEISTUNG: 1293KW BEI COS PHI = 1 UND UN = 690V | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SE7141-2HM62-5BA0 | SIMOVERT MASTERDRIVES VECTOR CONTROL EINSPEISE-RUECKSPEISE-EINHEIT SELBSTGEFUEHRT U. GEPULST (AFE) SCHRANKGERAET, SCHUTZART IP20 3 AC 600-690V, 50/60HZ, 1230A TYPENLEISTUNG: 1200KW | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SE7141-3EH80-2BA0 | SIMOVERT MASTERDRIVES VECTOR CONTROL EIN-/RUECKSPEISE-EINHEIT SELBSTGEFUEHRT U. GEPULST (AFE) SCHRANKGERAET, SCHUTZART IP20 3 AC 380-480V, 50/60HZ BEMESSUNGSEINGANGSSTROM: 1235A TYPENLEISTUNG: 836KW BEI COS PHI = 1 UND UN = 400V | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SE7141-3EM62-5BA0 | SIMOVERT MASTERDRIVES VECTOR CONTROL EINSPEISE-RUECKSPEISE-EINHEIT SELBSTGEFUEHRT U. GEPULST (AFE) SCHRANKGERAET, SCHUTZART IP20 3 AC 380-480V, 50/60HZ, 1300A TYPENLEISTUNG: 710KW | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1145-1AA00-0AA0 | SIMODRIVE 611-A/611-D INFEED MODULE, 10/25 KW, NON-STABILIZED | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1145-1AA00-0CA0 | SIMODRIVE 611A/D INFEED MODULE, 28/50 KW, UNREGULATED, FOR INTERNAL COOL. | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1145-1AA01-0AA0 | SIMODRIVE 611 INFEED MODULE, 10/25 KW, NON-STABILIZED, NETWORK PROTECTION WITH NORMALLY CLOSED CONTACT | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1145-1AA01-0AA1 | SIMODRIVE 611 INFEED MODULE, 10/25 KW, UNREGULATED, INTERNAL/EXTERNAL COOLING, MAINS CONTACTOR WITH BREAK CONTACT | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1145-1BA00-0BA0 | SIMODRIVE 611-A/611-D INFEED/REGENERATIVE FEEDBACK MODULE, 16/21 KW STABILIZED | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1145-1BA00-0CA0 | SIMODRIVE 611-A/D INFEED/REGENERATIVE FEEDBACK MODULE, 36/47 KW STABILIZED | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1145-1BA00-0DA0 | SIMODRIVE 611-A/D INFEED/REGENERATIVE FEEDBACK MODULE, 55/71 KW STABILIZED | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1145-1BA01-0BA0 | SIMODRIVE 611 INFEED/REGENERATIVE FEEDBACK MODULE, 16/21 KW STABILIZED; MAINS PROTECTION WITH NORMALLY CLOSED CONTACT | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1145-1BA01-0BA1 | SIMODRIVE 611 INFEED/REGENERATIVE FEEDBACK MODULE, 16/21 KW STABILIZED; INTERNAL HEAT DISSIPATION MAINS PROTECTION WITH NORMALLY CLOSED CONTACT | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1145-1BA01-0DA0 | SIMODRIVE 611 INFEED/REGENERATIVE FEEDBACK MODULE, 55/71 KW STABILIZED; NETWORK PROTECTION WITH NORMALLY CLOSED CONTACT | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1145-1BA01-0DA1 | SIMODRIVE 611 INFEED/REGENERATIVE FEEDBACK MODULE 55/71 KW, STABILIZED, WITH INTERNAL COOLING, MAINS CONTACTOR WITH BREAK CONTACT | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1145-1BA02-0CA0 | SIMODRIVE 611 INFEED/REGENERATIVE FEEDBACK MODULE, 36/47 KW STABILIZED; NETWORK PROTECTION WITH NORMALLY CLOSED CONTACT | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1145-1BA02-0CA1 | SIMODRIVE 611 INFEED/REGENERATIVE FEEDBACK MODULE, 36/47 KW STABILIZED, INTERNAL HEAT DISSIPATION, MAINS PROTECTION WITH NORMALLY CLOSED CONTACT | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1145-1BB00-0DA0 | SIMODRIVE 611 INFEED/REGENERATIVE FEEDBACK MODULE, 55/71 KW STABILIZED; NETWORK PROTECTION WITH NC CONTACT FOR HOSE COOLER | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1145-1BB00-0DA1 | SIMODRIVE 611 INFEED/REGENERATIVE FEEDBACK MODULE, 55/71 KW CONTROLLED; LINE CONTACTOR WITH NC CONTACT FOR HOSE COOLER | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1145-1BB00-0EA0 | SIMODRIVE 611 INFEED/REGENERATIVE FEEDBACK MODULE, 80/104 KW STABILIZED; INTERNAL HEAT DISSIPATION | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1145-1BB00-0EA1 | SIMODRIVE 611 INFEED/REGEN.FEEDBACK MODULE 80/104 KW, CLOSED-LOOP CONTROL INTERNAL COOLING | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1145-1BB00-0FA0 | SIMODRIVE 611 INFEED/REGENERATIVE FEEDBACK MODULE, 120/156 KW STABILIZED; INTERNAL HEAT DISSIPATION | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1145-1BB00-0FA1 | SIMODRIVE 611 INFEED/REGEN.FEEDBACK MODULE 120/156 KW, CLOSED-LOOP CONTROL INTERNAL COOLING. | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1146-1AB00-0AA0 | SIMODRIVE 611 INFEED MODULE, 10/25 KW, NON-STABILIZED; EXTERNAL HEAT DISSIPATION | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1146-1AB00-0BA0 | SIMODRIVE 611-A/611-D INFEED MODULE,, 5/10 KW, NON-STABILIZED | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1146-1AB00-0BA1 | SIMODRIVE 611 INFEED MODULE, 5/10 KW, UNREGULATED, WITH INTERNAL/EXT. COOLING | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1146-1AB00-0CA0 | SIMODRIVE 611 INFEED MODULE, 28/50 KW, UNREGULATED, FOR EXTERNAL COOLING | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1146-1AB01-0AA0 | SIMODRIVE 611 INFEED MODULE, 10/25 KW, NON-STABILIZED; EXTERNAL HEAT DISSIPATION MAINS PROTECTION WITH NORMALLY CLOSED CONTACT | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1146-1BB00-0BA0 | SIMODRIVE 611 INFEED/REGENERATIVE FEEDBACK MODULE, 16/21 KW STABILIZED; EXTERNAL HEAT DISSIPATION | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1146-1BB00-0CA0 | SIMODRIVE 611-A/D INFEED/REGENERATIVE FEEDBACK MODULE, 36/47 KW STABILIZED; EXTERNAL HEAT DISSIPATION | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1146-1BB00-0DA0 | SIMODRIVE 611 INFEED/REGENERATIVE FEEDBACK MODULE, 55/71 KW STABILIZED; EXTERNAL HEAT DISSIPATION, MAINS PROTECTION WITH NORMALLY CLOSED CONTACT | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1146-1BB00-0DA1 | SIMODRIVE 611 INFEED/REGEN.FEEDBACK MODULE 55/71 KW, CLOSED-LOOP CONTROL, EXTERNAL COOLING, MAINS CONTACTOR WITH BREAK CONTACT | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1146-1BB00-0EA0 | SIMODRIVE 611 INFEED/REGENERATIVE FEEDBACK MODULE, 80/104 KW STABILIZED; EXTERNAL HEAT DISSIPATION | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1146-1BB00-0EA1 | SIMODRIVE 611 INFEED/REGEN.FEEDBACK MODULE 80/104 KW, CLOSED-LOOP CONTROL EXTERNAL COOLING. | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
6SN1146-1BB00-0FA0 | SIMODRIVE 611 INFEED/REGENERATIVE FEEDBACK MODULE, 120/156 KW STABILIZED; EXTERNAL HEAT DISSIPATION | Drive Technology | Rectifier / Regenerative Units | SIEMENS |
Repair of supply and regenerative units
Supply and regenerative units are mostly subject to heavy work load. Faults on these components lead to severe malfunctions of converters and attached machinery. In the field of driving automation EICHLER offers a large variety of repair and maintenance for not only current models in this field but also discontinued types. Especially discontinued supply and regenerative units cause a much larger investion in costs towards having to migrate this system compared to an expert repair.
Possible repairs of supply and regenerative units
- Repair of internal power supplies
- Possible Repair of the CU ( Control Unit )
- Mainstaining the drive-level of amplifiers
- Repair of amplifiers
- Recharging of faulty interfaces
- Strategic preventative maintenance
- Possible clearing of problems within the inner safety circuit
Quality management according to ISO 9001:2015
Certified workflow guarantees a consistently high quality of service when testing and repairing your component.
Nuclear Safety Committee 1401
As one of the first service providers, EICHLER is authorised to repair and sell automation and control technology in the nuclear sector.
Environmental management according to ISO 14001:2015
Standardized procedures for cleaning, repair and, if necessary, the disposal of components ensure a sustainable, environmentally sound use of resources.
Sale of supply and regenerative units
EICHLER offers a large variety of monitors of all kinds of make. Apart from current models we also are able to provide discontinued lines. The experts at Eichler constantly monitor the market in order to respond to discontinuations according to the individual manufacturers. Due to our contacts world-wide we are even able to provide you with monitors discontinued long ago. Every component we quote is refurbished completely at our Electronic-Service-Centre according to standardized proceedures and finally tested under full capacity with the help of specially designed test racks. Each item purchased, be it new or refurbished, is fitted out with a 24 months minimum warranty.
We stock more than 30.000 components
To be able to offer you a large variety of current and discontinued devices EICHLER manages an own stock level of over 30.000 components. This enables us to service you with the necessary module as very short notice – even in case of a breakdown in your system.
Function is fully tested
Every module you purchase at EICHLER is fully tested on all relevant functions before it leaves our works. The combination of highly experienced staff together with our specific Trial- and Testracks give you the necessary safety on the purchase of refurbished automation equipment.
Warranty included
Full trial runs give you the guarantee of the highest possible level on repair service and function of the part sent to us. The item returned to is fitted with a 24 months warranty. If you wish to have an optional test of all parameters we are able to extend this warranty up to 36 months.
Your Direct Line to EICHLER GmbH
Emergency-Hotline - Machine Breakdown
24/7 Spare Parts Service
Service-Hotline - Sales, Maintenance Contracts and Repairs
Technical Trainings - Information & Booking
Life Cycle Management - Information & Appointments
Purchase of Overstockings