Converters – Frequency Converters for power supply and control of electrical machinery and motors
Converters and frequency converters belong to the family of power modules in order to enable the direct supply of electrical engines and machinery with the necessary AC current. Some frequency converters, apart from being able to control and convert frequency and amplitude, also have sensoric input to control and evaluate additional parameters such as the current potition of the rotor and the number of revs running. Depending on the make of machinery some frequency converters are fitted with either single or 3-phase AC power supply. Some models are even able to convert a single phase power supply into 3-phase supplies in order to service rotary current electrical engines.
Repair
EICHLER is specialized in servicing frequency converters of numerous manufacturers. All modules are specifically repaired down to the individual component according to the actual damage recorded.
Sale
EICHLER offers a large variety of current and discontinued types of converters and frequency converters. Every module is fully tested and fitted with a 24 months warranty.
Product Overview
Should you not have the specific item number at hand kindly refer to the product overview. Here you will find all combined modules available online.
Product Overview – Converters – Frequency Converters
Following you fill see an overview of all converters available online. For further details referring to the individual item please klick on the article code accordingly. Should you nevertheless not be able to trace the item requested kindly use the intelligent search for components or simply give us a call: +49 8196 9000-110
Article Name | Article Description | Scope | Article Group Name | Manufacturer |
---|---|---|---|---|
FAS4020 | STÖBER Umrichter POSIDRVE FAS4000 1,1 kW; 2,9A; 3x 400V; integrierter Lüfter | Drive Technology | Frequency Converter | STÖBER |
131B4268 | DANFOSS Frequenzumrichter HVAC FC-102P30KT4E55H1XGXXXXSXXXXAXBXCXXXXDX 30,0 KW; 3x 380- 480V; IP55; EMV-Filter A1/B; graphisches LCP; | Drive Technology | Frequency Converter | DANFOSS |
MDS5110A | STÖBER Umrichter POSIDRIVE MDS5000 11,00 kW; Low Level, 24 V extern; | Drive Technology | Frequency Converter | STÖBER |
131H9382 | DANFOSS Frequenzumrichter FC-302P15KT5E20H1XGCXXXSXXXXA0BXCXXXXD0 15,0 KW; 3x 380-500V; IP20; EMV-Filter A1/B1; graphisches LCP; lackierte Platinen; MCA 101 Profibus DP V1; externe 24 V DC-Versorgung; | Drive Technology | Frequency Converter | DANFOSS |
6SE7023-4TC21-Z | SIMOVERT MASTERDRIVES SIMOVERT VC WECHSELRICHTERGERAET KOMPAKTGERAET, IP20 DC 510-620V 34A TYPENLEISTUNG: 15KW | Drive Technology | Frequency Converter | SIEMENS |
MKS51A015-503-50 | SEW MOVIDYN Servoumrichter MKS51A 15 A; 7,5 KW; inkl. Positionierung (IPOS); | Drive Technology | Frequency Converter | SEW |
175Z0069 | DANFOSS Frequenzumrichter VLT5000 VLT5008PT5B20EBR3D0F00A00C0 5,5 kW; 3x 380-500V; IP20; ohne LCP; Bremschopper, extern 24 V DC; 1A + 1B-Filter; | Drive Technology | Frequency Converter | DANFOSS |
195N1111 | DANFOSS Frequenzumrichter VLT2880 VLT2880PT4B20STR3DBF00A00C0 11,00 kW; 3x 380-480V; IP20; 1B-Filter; LCP; | Drive Technology | Frequency Converter | DANFOSS |
131H4596 | DANFOSS Frequenzumrichter HVAC FC-102P22KT4E20H1XGXXXXSXXXXA0BXCXXXXDX 22,0 kW; 3x 380-480 V; IP20; EMV-Filter A1/B; graphisches LCP; MCA 101 Profibus DP V1; | Drive Technology | Frequency Converter | DANFOSS |
175Z0567 | DANFOSS Frequenzumrichter VLT5000 VLT5008PT5B20SBR3D0F10A00C0 5,5 kW; 3x 380-500V; IP20; ohne LCP; mit Bremschopper; 1A + 1B-Filter; Profibus DP/FMS; | Drive Technology | Frequency Converter | DANFOSS |
131N9994 | DANFOSS Frequenzumrichter FC-302PK55T5E20H1XXXXXXSXXXXALBXCXXXXD0; 0,55 kW; 3x 380-500V; IP20; EMV-Filter A1/B1; Profinet; externe 24 V DC; ohne Display; | Drive Technology | Frequency Converter | DANFOSS |
ESMD751L4TXA | LENZE SMD-Frequenzumrichter 0,75 kW; 3x 400/480 V; IP20: | Drive Technology | Frequency Converter | Lenze |
6SE9612-7DF10-Z | MICROMASTER integrated MI110/3 Ausführung ohne Filter 3AC 380-500V +/-10% 47-63Hz Konstantmoment: 1.1kW Überlast 150% 60 Sek. quadratisches Moment: 1.1kW 105x 120x 160mm Schutzart IP65 Umgebungstemperatur -10 bis +50°C | Drive Technology | Frequency Converter | SIEMENS |
EVF8222-E-V020 | LENZE Frequenzumrichter 8220 22,0 kW; 47,0 A; HLK-Technik | Drive Technology | Frequency Converter | Lenze |
E84AVTCC1124SBS | LENZE Inverter Drives 8400 TopLine 1,1 kW; 3x 400/500V; mit integrierten Funkentstörmaßnahmen; Cold Plate - Technik; STO integriert; | Drive Technology | Frequency Converter | Lenze |
E82EV552K4B | LENZE Frequenzumrichter 8200 Vector 5,5 KW; 3 x 400 / 500 V; In: 50/60Hz; Out: 0-650Hz | Drive Technology | Frequency Converter | Lenze |
33.8307_E | LENZE Frequenzumrichter 33.8307 3x400/415V; 5.6A; 0-240Hz | Drive Technology | Frequency Converter | Lenze |
175Z7058 | DANFOSS Frequenzumrichter VLT6000 VLT6042HT4C54STR3DLF00A00C0 30,00 kW; 380-460 V; K. IP54; A1 + B-Filter ; LCP; | Drive Technology | Frequency Converter | DANFOSS |
EVS9321-ETV907 | LENZE Servo PLC 9300 Umrichter 0,37 KW; Technologieausführung | Drive Technology | Frequency Converter | Lenze |
6SL3210-1PE33-0AL0 | SINAMICS G120/S120 POWER MODULE PM240-2 FSG INTEGRIERTER FILTER EMV-KAT C2 MIT INTEGRIERTEM BREMS-CHOPPER 3AC380-480V+10/-10% 47-63HZ LEISTUNG HOHE UEBERLAST: 132KW BEI 200% 3S, 150% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +50°C (HO), LEISTUNG GERINGE UEBERLAST: 160KW BEI 150% 3S, 110% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +40°C (LO) 1000X305X357 (HXBXT), FSG SCHUTZART IP20 OHNE CONTROL UNIT UND BEDIENEINHEIT FREIGEGEBEN AB CU FIRMWARE- VERSION V4.7 SP9 UND V5.1 | Drive Technology | Frequency Converter | SIEMENS |
6SL3210-1PE33-0CL0 | SINAMICS G120/S120 POWER MODULE PM240-2 FSG INTEGRIERTEM FILTER EMV-KAT C3 MIT INTEGRIERTEM BREMS-CHOPPER 3AC380-480V+10/-10% 47-63HZ LEISTUNG HOHE UEBERLAST: 132KW BEI 200% 3S, 150% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +50°C (HO), LEISTUNG GERINGE UEBERLAST: 160KW BEI 150% 3S, 110% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +40°C (LO) 1000X305X357 (HXBXT), FSG SCHUTZART IP20 OHNE CONTROL UNIT UND BEDIENEINHEIT FREIGEGEBEN AB CU FIRMWARE- VERSION V4.7 SP9 UND V5.1 | Drive Technology | Frequency Converter | SIEMENS |
6SL3210-1PE33-7AL0 | SINAMICS G120/S120 POWER MODULE PM240-2 FSG C2 MIT INTEGRIERTEM BREMS-CHOPPER 3AC380-480V+10/-10% 47-63HZ LEISTUNG HOHE UEBERLAST: 160KW BEI 200% 3S, 150% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +50°C (HO), LEISTUNG GERINGE UEBERLAST: 200KW BEI 150% 3S, 110% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +40°C (LO) 1000X305X357 (HXBXT), FSG SCHUTZART IP20 OHNE CONTROL UNIT UND BEDIENEINHEIT FREIGEGEBEN AB CU FIRMWARE- VERSION V4.7 SP9 UND V5.1 | Drive Technology | Frequency Converter | SIEMENS |
6SL3210-1PE33-7CL0 | SINAMICS G120/S120 POWER MODULE PM240-2 FSG INTEGRIERTER FILTER EMV-KAT C3 MIT INTEGRIERTEM BREMS-CHOPPER 3AC380-480V+10/-10% 47-63HZ LEISTUNG HOHE UEBERLAST: 160KW BEI 200% 3S, 150% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +50°C (HO), LEISTUNG GERINGE UEBERLAST: 200KW BEI 150% 3S, 110% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +40°C (LO) 1000X305X357 (HXBXT), FSG SCHUTZART IP20 OHNE CONTROL UNIT UND BEDIENEINHEIT FREIGEGEBEN AB CU FIRMWARE- VERSION V4.7 SP9 UND V5.1 | Drive Technology | Frequency Converter | SIEMENS |
6SL3210-1PE34-8AL0 | SINAMICS G120/S120 POWER MODULE PM240-2 FSG C2 MIT INTEGRIERTEM BREMS-CHOPPER 3AC380-480V+10/-10% 47-63HZ LEISTUNG HOHE UEBERLAST: 200KW BEI 200% 3S, 150% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +50°C (HO), LEISTUNG GERINGE UEBERLAST: 250KW BEI 150% 3S, 110% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +40°C (LO) 1000X305X357 (HXBXT), FSG SCHUTZART IP20 OHNE CONTROL UNIT UND BEDIENEINHEIT FREIGEGEBEN AB CU FIRMWARE- VERSION V4.7 SP9 UND V5.1 | Drive Technology | Frequency Converter | SIEMENS |
6SL3210-1PE34-8CL0 | SINAMICS G120/S120 POWER MODULE PM240-2 FSG C3 MIT INTEGRIERTEM BREMS-CHOPPER 3AC380-480V+10/-10% 47-63HZ LEISTUNG HOHE UEBERLAST: 200KW BEI 200% 3S, 150% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +50°C (HO), LEISTUNG GERINGE UEBERLAST: 250KW BEI 150% 3S, 110% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +40°C (LO) 1000X305X357 (HXBXT), FSG SCHUTZART IP20 OHNE CONTROL UNIT UND BEDIENEINHEIT FREIGEGEBEN AB CU FIRMWARE- VERSION V4.7 SP9 UND V5.1 | Drive Technology | Frequency Converter | SIEMENS |
6SL3210-1PH31-7CL0 | SINAMICS G120/S120 POWER MODULE PM240-2 FSG C3 MIT INTEGRIERTEM BREMS-CHOPPER 3AC500-690V+10/-10% 47-63HZ LEISTUNG HOHE UEBERLAST: 132KW BEI 200% 3S, 150% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +50°C (HO), LEISTUNG GERINGE UEBERLAST: 160KW BEI 150% 3S, 110% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +40°C (LO) 1000X305X357 (HXBXT), FSG SCHUTZART IP20 OHNE CONTROL UNIT UND BEDIENEINHEIT FREIGEGEBEN AB CU FIRMWARE- VERSION V4.7 SP9 UND V5.1 | Drive Technology | Frequency Converter | SIEMENS |
6SL3210-1PH32-1CL0 | SINAMICS G120/S120 POWER MODULE PM240-2 FSG C3 MIT INTEGRIERTEM BREMS-CHOPPER 3AC500-690V+10/-10% 47-63HZ LEISTUNG HOHE UEBERLAST: 160KW BEI 200% 3S, 150% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +50°C (HO), LEISTUNG GERINGE UEBERLAST: 200KW BEI 150% 3S, 110% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +40°C (LO) 1000X305X357 (HXBXT), FSG SCHUTZART IP20 OHNE CONTROL UNIT UND BEDIENEINHEIT FREIGEGEBEN AB CU FIRMWARE- VERSION V4.7 SP9 UND V5.1 | Drive Technology | Frequency Converter | SIEMENS |
6SL3210-1PH32-5CL0 | SINAMICS G120/S120 POWER MODULE PM240-2 FSG C3 MIT INTEGRIERTEM BREMS-CHOPPER 3AC500-690V+10/-10% 47-63HZ LEISTUNG HOHE UEBERLAST: 200KW BEI 200% 3S, 150% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +50°C (HO), LEISTUNG GERINGE UEBERLAST: 250KW BEI 150% 3S, 110% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +40°C (LO) 1000X305X357 (HXBXT), FSG SCHUTZART IP20 OHNE CONTROL UNIT UND BEDIENEINHEIT FREIGEGEBEN AB CU FIRMWARE- VERSION V4.7 SP9 UND V5.1 | Drive Technology | Frequency Converter | SIEMENS |
6SL3210-5BB21-1BV1 | SINAMICS V20 1 AC 200-240 V - 10/+ 10 % 47-6 NENNLEISTUNG 1,1 KW MIT 150 % UEBERLAST FUER 60 SEK. INTEGRIERTER FILTER C1 E/A-SCHNITTSTELLE: 4 DI, 2 DO, FELDBUS: USS/MODBUS RTU MIT EINGEBAUTEM BOP SCHUTZ: IP20/ UL OFFEN BAUGR.: BAUGR. AC 160X90X147(HXBXT) | Drive Technology | Frequency Converter | SIEMENS |
6SL3210-5BB21-1UV1 | SINAMICS V20 1 AC 200-240 V - 10/+ 10 % 47-6 NENNLEISTUNG 1,1 KW MIT 150 % UEBERLAST FUER 60 SEK. UNGEFILTERT E/A-SCHNITTSTELLE: 4 DI, 2 DO, FELDBUS: USS/MODBUS RTU MIT EINGEBAUTEM BOP SCHUTZ: IP20/ UL OFFEN BAUGR.: BAUGR. AC 160X90X147(HXBXT) | Drive Technology | Frequency Converter | SIEMENS |
6SL3210-5BB21-5BV1 | SINAMICS V20 1 AC 200-240 V - 10/+ 10 % 47-6 NENNLEISTUNG 1,5 KW MIT 150 % UEBERLAST FUER 60 SEK. INTEGRIERTER FILTER C1 E/A-SCHNITTSTELLE: 4 DI, 2 DO, FELDBUS: USS/MODBUS RTU MIT EINGEBAUTEM BOP SCHUTZ: IP20/ UL OFFEN BAUGR.: BAUGR. AC 160X90X147(HXBXT) | Drive Technology | Frequency Converter | SIEMENS |
6SL3210-5BB21-5UV1 | SINAMICS V20 1 AC 200-240 V - 10/+ 10 % 47-6 NENNLEISTUNG 1,5 KW MIT 150 % UEBERLAST FUER 60 SEK. UNGEFILTERT E/A-SCHNITTSTELLE: 4 DI, 2 DO, FELDBUS: USS/MODBUS RTU MIT EINGEBAUTEM BOP SCHUTZ: IP20/ UL OFFEN BAUGR.: BAUGR. AC 160X90X147(HXBXT) | Drive Technology | Frequency Converter | SIEMENS |
6SL3210-5FB10-1UA1 | SINAMICS V90, EINGANGSSPANNUNG: 200-240 V 1/3-PHASEN-AC - 15 %/+ 10 % 2,5 A/1,5 A 45-66 AUSGANGSSPANNUNG: 0 – EINGANGSS 1,2 A 0-330 HZ MOTOR: 0,1 KW SCHUTZART: IP20 BAUGROESSE A, 45X170X170 (BXHXT) | Drive Technology | Frequency Converter | SIEMENS |
6SL3210-5FB10-1UF1 | SINAMICS V90, MIT PROFINET EINGANGSSPANNUNG: 200-240 V 1/3-PHASEN-AC - 15 %/+ 10 % 2,5 A/1,5 A 45-66 AUSGANGSSPANNUNG: 0 – EINGANGSS 1,2 A 0-330 HZ MOTOR: 0,1 KW SCHUTZART: IP20 BAUGROESSE A, 45X170X170 (BXHXT) | Drive Technology | Frequency Converter | SIEMENS |
6SL3210-5FB10-2UA1 | SINAMICS V90, EINGANGSSPANNUNG: 200-240 V 1/3-PHASEN-AC - 15 %/+ 10 % 3,0 A/1,8 A 45-66 AUSGANGSSPANNUNG: 0 – EINGANGSS 1,4 A 0-330 HZ MOTOR: 0,2 KW SCHUTZART: IP20 BAUGROESSE A, 45X170X170 (BXHXT) | Drive Technology | Frequency Converter | SIEMENS |
6SL3210-5FB10-2UF1 | SINAMICS V90, MIT PROFINET EINGANGSSPANNUNG: 200-240 V 1/3-PHASEN-AC - 15 %/+ 10 % 3,0 A/1,8 A 45-66 AUSGANGSSPANNUNG: 0 – EINGANGSS 1,4 A 0-330 HZ MOTOR: 0,2 KW SCHUTZART: IP20 BAUGROESSE A, 45X170X170 (BXHXT) | Drive Technology | Frequency Converter | SIEMENS |
6SL3210-5HB10-1UF0 | SINAMICS S210 EINGANGSSPANNUNG: 1AC 200-240V; -10%/+10%; 1,4A; 45-66HZ; AUSGANGSSPANNUNG: 0-EINGABE V; 0,8A; 0-550HZ; MOTOR: 0,1KW; SCHUTZKLASSE: IP20; FRAME SIZE A; 45 X 170 X 170 (BXHXT) | Drive Technology | Frequency Converter | SIEMENS |
6SL3210-5HB10-2UF0 | SINAMICS S210 EINGANGSSPANNUNG: 1AC 200-240V; -10%/+10%; 2,7A; 45-66HZ; AUSGANGSSPANNUNG: 0-EINGABE V; 1,4A; 0-550HZ; MOTOR: 0,2KW; SCHUTZKLASSE: IP20; FRAME SIZE A; 45 X 170 X 170 (BXHXT) | Drive Technology | Frequency Converter | SIEMENS |
6SL3210-5HB10-4UF0 | SINAMICS S210 EINGANGSSPANNUNG: 1AC 200-240V; -10%/+10%; 5,0A; 45-66HZ; AUSGANGSSPANNUNG: 0-EINGABE V; 2,4A; 0-550HZ; MOTOR: 0,4KW; SCHUTZKLASSE: IP20; FRAME SIZE B; 55 X 170 X 170 (BXHXT) | Drive Technology | Frequency Converter | SIEMENS |
6SL3210-5HB10-8UF0 | SINAMICS S210 EINGANGSSPANNUNG: 1AC 200-240V; -10%/+10%; 9,3A; 45-66HZ; AUSGANGSSPANNUNG: 0-EINGABE V; 4,4A; 0-550HZ; MOTOR: 0,75KW; SCHUTZKLASSE: IP20; FRAME SIZE C; 75 X 170 X 195 (BXHXT) | Drive Technology | Frequency Converter | SIEMENS |
6SL3211-1PC26-8UL0 | SINAMICS G120 POWER MODULE PM 240-2 PUSH THROUGH, UNGEFILTERT MIT INTEGRIERTEM BREMS-CHOPPER 3AC200-240V+10/-20% 47-63HZ LEISTUNG HOHE UEBERLAST: 15KW BEI 200% 3S, 150% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +50°C (HO); LEISTUNG GERINGE UEBERLAST: 18,5KW BEI 150% 3S, 110% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +40°C (LO) 517X275X237 (HXBXT), FSD SCHUTZART IP20 OHNE CONTROL UNIT UND BEDIENEINHEIT FREIGEGEBEN AB CU FIRMWARE- VERSION V4.7 SP6 | Drive Technology | Frequency Converter | SIEMENS |
6SL3211-1PC31-1UL0 | SINAMICS G120 POWER MODULE PM 240-2 PUSH THROUGH, UNGEFILTERT MIT INTEGRIERTEM BREMS-CHOPPER 3AC200-240V+10/-20% 47-63HZ LEISTUNG HOHE UEBERLAST: 22KW BEI 200% 3S, 150% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +50°C (HO); LEISTUNG GERINGE UEBERLAST: 30KW BEI 150% 3S, 110% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +40°C (LO) 615X354X237 (HXBXT), FSE SCHUTZART IP20 OHNE CONTROL UNIT UND BEDIENEINHEIT FREIGEGEBEN AB CU FIRMWARE- VERSION V4.7 SP6 | Drive Technology | Frequency Converter | SIEMENS |
6SL3211-1PC31-8UL0 | SINAMICS G120 POWER MODULE PM240-2 PUSH THROUGH, UNGEFILTERT MIT INTEGRIERTEM BREMS-CHOPPER 3AC200-240V+10/-20% 47-63HZ LEISTUNG HOHE UEBERLAST: 45KW BEI 200% 3S, 150% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +50°C (HO); LEISTUNG GERINGE UEBERLAST: 55KW BEI 150% 3S, 110% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +40°C (LO) 754X384X358 (HXBXT), FSF SCHUTZART IP20 OHNE CONTROL UNIT UND BEDIENEINHEIT FREIGEGEBEN AB CU FIRMWARE- VERSION V4.7 SP6 | Drive Technology | Frequency Converter | SIEMENS |
6SL3211-1PE27-5AL0 | SINAMICS G120 POWER MODULE PM240-2 PUSH THROUGH, MIT INTEGRIERTEM KLASSE-A-FILTER MIT INTEGRIERTEM BREMS-CHOPPER 3AC380-480V+10/-20% 47-63HZ LEISTUNG HOHE UEBERLAST: 30KW BEI 200% 3S, 150% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +50°C (HO); LEISTUNG GERINGE UEBERLAST: 37KW BEI 150% 3S, 110% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +40°C (LO) 517X275X237 (HXBXT), FSD SCHUTZART IP20 OHNE CONTROL UNIT UND BEDIENEINHEIT FREIGEGEBEN AB CU FIRMWARE- VERSION V4.7 SP6 | Drive Technology | Frequency Converter | SIEMENS |
6SL3211-1PE27-5UL0 | SINAMICS G120 POWER MODULE PM240-2 PUSH THROUGH, UNGEFILTERT MIT INTEGRIERTEM BREMS-CHOPPER 3AC380-480V+10/-20% 47-63HZ LEISTUNG HOHE UEBERLAST: 30KW BEI 200% 3S, 150% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +50°C (HO); LEISTUNG GERINGE UEBERLAST: 37KW BEI 150% 3S, 110% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +40°C (LO) 517X275X237 (HXBXT), FSD SCHUTZART IP20 OHNE CONTROL UNIT UND BEDIENEINHEIT FREIGEGEBEN AB CU FIRMWARE- VERSION V4.7 SP6 | Drive Technology | Frequency Converter | SIEMENS |
6SL3211-1PE31-1AL0 | SINAMICS G120 POWER MODULE PM 240-2 PUSH THROUGH, MIT INTEGRIERTEM KLASSE-A-FILTER MIT INTEGRIERTEM BREMS-CHOPPER 3AC380-480V+10/-20% 47-63HZ LEISTUNG HOHE UEBERLAST: 45KW BEI 200% 3S, 150% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +50°C (HO); LEISTUNG GERINGE UEBERLAST: 55KW BEI 150% 3S, 110% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +40°C (LO) 615X354X237 (HXBXT), FSE SCHUTZART IP20, OHNE CONTROL UNIT UND BEDIENEINHEIT FREIGEGEBEN AB CU FIRMWARE- VERSION V4.7 SP6 | Drive Technology | Frequency Converter | SIEMENS |
6SL3211-1PE31-1UL0 | SINAMICS G120 POWER MODULE PM 240-2 PUSH THROUGH, UNGEFILTERT MIT INTEGRIERTEM BREMS-CHOPPER 3AC380-480V+10/-20% 47-63HZ LEISTUNG HOHE UEBERLAST: 45KW BEI 200% 3S, 150% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +50°C (HO); LEISTUNG GERINGE UEBERLAST: 55KW BEI 150% 3S, 110% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +40°C (LO) 615X354X237 (HXBXT), FSE SCHUTZART IP20 OHNE CONTROL UNIT UND BEDIENEINHEIT FREIGEGEBEN AB CU FIRMWARE- VERSION V4.7 SP6 | Drive Technology | Frequency Converter | SIEMENS |
6SL3211-1PE32-5AL0 | SINAMICS G120 POWER MODULE PM 240-2 PUSH THROUGH, MIT INTEGRIERTEM KLASSE-A-FILTER MIT INTEGRIERTEM BREMS-CHOPPER 3AC380-480V+10/-20% 47-63HZ LEISTUNG HOHE UEBERLAST: 110KW BEI 200% 3S, 150% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +50°C (HO); LEISTUNG GERINGE UEBERLAST: 132KW BEI 150% 3S, 110% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +40°C (LO) 754X384X358 (HXBXT), FSF SCHUTZART IP20, OHNE CONTROL UNIT UND BEDIENEINHEIT FREIGEGEBEN AB CU FIRMWARE- VERSION V4.7 SP6 | Drive Technology | Frequency Converter | SIEMENS |
6SL3211-1PE32-5UL0 | SINAMICS G120 POWER MODULE PM 240-2 PUSH THROUGH, UNGEFILTERT MIT INTEGRIERTEM BREMS-CHOPPER 3AC380-480V+10/-20% 47-63HZ LEISTUNG HOHE UEBERLAST: 110KW BEI 200% 3S, 150% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +50°C (HO); LEISTUNG GERINGE UEBERLAST: 132KW BEI 150% 3S, 110% 57S, 100% 240S; UMGEBUNGSTEMPERATUR -20 BIS +40°C (LO) 754X384X358 (HXBXT), FSF SCHUTZART IP20 OHNE CONTROL UNIT UND BEDIENEINHEIT FREIGEGEBEN AB CU FIRMWARE- VERSION V4.7 SP6 | Drive Technology | Frequency Converter | SIEMENS |
6SL3351-1AE36-1BA1 | SINAMICS ERSATZ POWERBLOCK FUER 3AC 380-480V, 50/60HZ, 605A AC DRIVE/POWER MODULE GLEICHRICHTER UND U PHASE LACKIERTE BAUGRUPPEN UND VERNICKELTE STROMSCHIENEN | Drive Technology | Frequency Converter | SIEMENS |
Repairs Converters – Frequency Converters
In the field of driving automation EICHLER offers a large variety of repair and maintenance for converters and frequency converters. Numerous kinds of make such as Siemens, SEW, Lenze, Danfoss, Bosch, ABB - amongst many others - can be serviced at our works. Especially discontinued types of frequency converters cause a much larger investion in costs towards having to migrate this system compared to an expert repair.
Possible Repairs – Converters – Frequency Converters
- Removal of possible faults within the CU
- Repairs on the Internal Power Supply
- Repairs of faults within the intermediate circuit
- Maintaining the drive-level of amplifiers
- Trouble Shooting on electric recovery systems
- Problems with the interface
- Clearing possible faults within the internal safety controls
- Strategic preventative maintenance
Quality management according to ISO 9001:2015
Certified workflow guarantees a consistently high quality of service when testing and repairing your component.
Nuclear Safety Committee 1401
As one of the first service providers, EICHLER is authorised to repair and sell automation and control technology in the nuclear sector.
Environmental management according to ISO 14001:2015
Standardized procedures for cleaning, repair and, if necessary, the disposal of components ensure a sustainable, environmentally sound use of resources.
Sale on a large variety of new and refurbished frequency converters
EICHLER offers a large variety of current and discontinued types of converters. Every module is fully tested and fitted with a 24 months warranty and enables you to build up or restock your spareparts deposit.
We stock more than 30.000 components
To be able to offer you a large variety of current and discontinued devices EICHLER manages an own stock level of over 30.000 components. This enables us to service you with the necessary module as very short notice – even in case of a breakdown in your system.
Function is fully tested
Every module you purchase at EICHLER is fully tested on all relevant functions before it leaves our works. The combination of highly experienced staff together with our specific Trial- and Testracks give you the necessary safety on the purchase of refurbished automation equipment.
Warranty included
Full trial runs give you the guarantee of the highest possible level on repair service and function of the part sent to us. The item returned to is fitted with a 24 months warranty. If you wish to have an optional test of all parameters we are able to extend this warranty up to 36 months.
Your Direct Line to EICHLER GmbH
Emergency-Hotline - Machine Breakdown
24/7 Spare Parts Service
Service-Hotline - Sales, Maintenance Contracts and Repairs
Technical Trainings - Information & Booking
Life Cycle Management - Information & Appointments
Purchase of Overstockings