Frequency Converter – Driving Automation
Intelligent Search for Components
Search according to your product code, category of product or manufacturer and you will find your requested component fast and easy. Should you nevertheless not be able to trace the part you are looking for – our experts will gladly help you Tel: +49 8196 9000-110.
Converters – Frequency Converters for power supply and control of electrical machinery and motors
Converters and frequency converters belong to the family of power modules in order to enable the direct supply of electrical engines and machinery with the necessary AC current. Some frequency converters, apart from being able to control and convert frequency and amplitude, also have sensoric input to control and evaluate additional parameters such as the current potition of the rotor and the number of revs running. Depending on the make of machinery some frequency converters are fitted with either single or 3-phase AC power supply. Some models are even able to convert a single phase power supply into 3-phase supplies in order to service rotary current electrical engines.
Repair
EICHLER is specialized in servicing frequency converters of numerous manufacturers. All modules are specifically repaired down to the individual component according to the actual damage recorded.
Sale
EICHLER offers a large variety of current and discontinued types of converters and frequency converters. Every module is fully tested and fitted with a 24 months warranty.
Product Overview
Should you not have the specific item number at hand kindly refer to the product overview. Here you will find all combined modules available online.
Product Overview – Converters – Frequency Converters
Following you fill see an overview of all converters available online. For further details referring to the individual item please klick on the article code accordingly. Should you nevertheless not be able to trace the item requested kindly use the intelligent search for components or simply give us a call: +49 8196 9000-110
Article Name | Article Description | Scope | Article Group Name | Manufacturer |
---|---|---|---|---|
6SL3211-0KB13-7BB1 | SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 0.37KW; VT: 0.37KW CT-OVERLOAD: 150% 60S 150 X 90 X 101 (HXWXD) IP20; WITH FLAT HEATSINK; COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT ANALOG INPUT | Drive Technology | Frequency Converter | SIEMENS |
6SL3211-0KB13-7UA1 | SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0.37KW; VT: 0.37KW CT-OVERLOAD: 150% 60S 150 X 90 X 101 (HXWXD) IP20; WITH FLAT HEATSINK; COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE | Drive Technology | Frequency Converter | SIEMENS |
6SL3211-0KB13-7UB1 | SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 0.37KW; VT: 0.37KW CT-OVERLOAD: 150% 60S 150 X 90 X 101 (HXWXD) IP20; WITH FLAT HEATSINK; COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT ANALOG INPUT | Drive Technology | Frequency Converter | SIEMENS |
6SL3211-0KB15-5BA1 | SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0.55KW; VT: 0.55KW CT-OVERLOAD: 150% 60S 150 X 90 X 101 (HXWXD) IP20; WITH FLAT HEATSINK; COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE | Drive Technology | Frequency Converter | SIEMENS |
6SL3211-0KB15-5BB1 | SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 0.55KW; VT: 0.55KW CT-OVERLOAD: 150% 60S 150 X 90 X 101 (HXWXD) IP20; WITH FLAT HEATSINK; COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT ANALOG INPUT | Drive Technology | Frequency Converter | SIEMENS |
6SL3211-0KB15-5UA1 | SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0.55KW; VT: 0.55KW CT-OVERLOAD: 150% 60S 150 X 90 X 101 (HXWXD) IP20; WITH FLAT HEATSINK; COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE | Drive Technology | Frequency Converter | SIEMENS |
6SL3211-0KB15-5UB1 | SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 0.55KW; VT: 0.55KW CT-OVERLOAD: 150% 60S 150 X 90 X 101 (HXWXD) IP20; WITH FLAT HEATSINK; COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT ANALOG INPUT | Drive Technology | Frequency Converter | SIEMENS |
6SL3211-0KB17-5BA1 | SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0.75KW; VT: 0.75KW CT-OVERLOAD: 150% 60S 150 X 90 X 101 (HXWXD) IP20; WITH FLAT HEATSINK; COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +40 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE | Drive Technology | Frequency Converter | SIEMENS |
6SL3211-0KB17-5BB1 | SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 0.75KW; VT: 0.75KW CT-OVERLOAD: 150% 60S 150 X 90 X 101 (HXWXD) IP20; WITH FLAT HEATSINK; COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +40 DEG C WITHOUT BOP WITHOUT ANALOG INPUT | Drive Technology | Frequency Converter | SIEMENS |
6SL3211-0KB17-5UA1 | SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0.75KW; VT: 0.75KW CT-OVERLOAD: 150% 60S 150 X 90 X 101 (HXWXD) IP20; WITH FLAT HEATSINK; COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +40 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE | Drive Technology | Frequency Converter | SIEMENS |
6SL3211-0KB17-5UB1 | SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 0.75KW; VT: 0.75KW CT-OVERLOAD: 150% 60S 150 X 90 X 101 (HXWXD) IP20; WITH FLAT HEATSINK; COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +40 DEG C WITHOUT BOP WITHOUT ANALOG INPUT | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE13-7UA0 | SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 0,37KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C 173 X 73 X 145 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE15-5UA0 | SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 0,55KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C 173 X 73 X 145 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE17-5UA0 | SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 0,75KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C 173 X 73 X 145 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE21-1UA0 | SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 1,1KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C 173 X 73 X 145 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE21-5UA0 | SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 1,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C 173 X 73 X 145 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE22-2AA0 | SINAMICS G120 POWER MODULE PM240 WITH BUILT IN CL. A FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 2,2KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C 270 X 153 X 165 (HXWXD), FSB PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE22-2UA0 | SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 2,2KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C 270 X 153 X 165 (HXWXD), FSB PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE23-0AA0 | SINAMICS G120 POWER MODULE PM240 WITH BUILT IN CL. A FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 3,0KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C 270 X 153 X 165 (HXWXD), FSB PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE23-0UA0 | SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 3,0KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C 270 X 153 X 165 (HXWXD), FSB PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE24-0AA0 | SINAMICS G120 POWER MODULE PM240 WITH BUILT IN CL. A FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 4,0KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C 270 X 153 X 165 (HXWXD), FSB PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE24-0UA0 | SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 4,0KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C 270 X 153 X 165 (HXWXD), FSB PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE25-5AA0 | SINAMICS G120 POWER MODULE PM240 WITH BUILT IN CL. A FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 5,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 7,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 334 X 189 X 185 (HXWXD), FSC PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE25-5UA0 | SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 5,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 7,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 334 X 189 X 185 (HXWXD), FSC PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE27-5AA0 | SINAMICS G120 POWER MODULE PM240 WITH BUILT IN CL. A FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 7,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 11KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 334 X 189 X 185 (HXWXD), FSC PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE27-5UA0 | SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 7,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 11KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 334 X 189 X 185 (HXWXD), FSC PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE31-1AA0 | SINAMICS G120 POWER MODULE PM240 WITH BUILT IN CL. A FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 11KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 15KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 334 X 189 X 185 (HXWXD), FSC PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE31-1UA0 | SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 11KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 15KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 334 X 189 X 185 (HXWXD), FSC PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE31-5AA0 | SINAMICS G120 POWER MODULE PM240 WITH BUILT IN CL. A FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 15KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 18,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 512 X 275 X 204 (HXWXD), FSD PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE31-5UA0 | SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 15KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 18,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 419 X 275 X 204 (HXWXD), FSD PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE31-8AA0 | SINAMICS G120 POWER MODULE PM240 WITH BUILT IN CL. A FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 18,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 22KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 512 X 275 X 204 (HXWXD), FSD PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE31-8UA0 | SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 18,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 22KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 419 X 275 X 204 (HXWXD), FSD PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE32-2AA0 | SINAMICS G120 POWER MODULE PM240 WITH BUILT IN CL. A FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 22KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 30KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 512 X 275 X 204 (HXWXD), FSD PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE32-2UA0 | SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 22KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 30KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 419 X 275 X 204 (HXWXD), FSD PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE33-0AA0 | SINAMICS G120 POWER MODULE PM240 WITH BUILT IN CL. A FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 30KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 37KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 635 X 275 X 204 (HXWXD), FSE PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE33-0UA0 | SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 30KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 37KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 497 X 275 X 204 (HXWXD), FSE PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE33-7AA0 | SINAMICS G120 POWER MODULE PM240 WITH BUILT IN CL. A FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 37KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 45KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 635 X 275 X 204 (HXWXD), FSE PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE33-7UA0 | SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 37KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 45KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 497 X 275 X 204 (HXWXD), FSE PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE34-5AA0 | SINAMICS G120 POWER MODULE PM240 WITH BUILT IN CL. A FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 45KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 55KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 934 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE34-5UA0 | SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 45KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 55KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 634 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE35-5AA0 | SINAMICS G120 POWER MODULE PM240 WITH BUILT IN CL. A FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 55KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 75KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 934 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE35-5UA0 | SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 55KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 75KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 634 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE37-5AA0 | SINAMICS G120 POWER MODULE PM240 WITH BUILT IN CL. A FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 75KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 90KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 934 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3224-0BE37-5UA0 | SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 75KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 90KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 634 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP | Drive Technology | Frequency Converter | SIEMENS |
6SL3225-0SE17-5UA0 | FREQUENZUMRICHTER FUER ET 200S LEISTUNGSTEIL IPM25 MODULBREITE 65 MM 3AC380-480V +10/-15% 47-63HZ LEISTUNG 0,75 KW UEBERLAST 150% 60S, 200% 3S NETZRUECKSPEISUNG ERWEITERBAR MIT BRAKE CONTROL MODUL OPTION: EXT. EMV-FILTER (KL. A) | Drive Technology | Frequency Converter | SIEMENS |
6SL3225-0SE22-2UA0 | FREQUENZUMRICHTER FUER ET 200S LEISTUNGSTEIL IPM25 MODULBREITE 130 MM 3AC380-480V +10/-15% 47-63HZ LEISTUNG 2,2 KW UEBERLAST 150% 60S, 200% 3S NETZRUECKSPEISUNG ERWEITERBAR MIT BRAKE CONTROL MODUL OPTION: EXT. EMV-FILTER (KL. A) (Sinamics) | Drive Technology | Frequency Converter | SIEMENS |
6SL3225-0SE24-0UA0 | FREQUENZUMRICHTER FUER ET 200S LEISTUNGSTEIL IPM25 MODULBREITE 130 MM 3AC380-480V +10/-15% 47-63HZ LEISTUNG 4,0 KW UEBERLAST 150% 60S, 200% 3S NETZRUECKSPEISUNG ERWEITERBAR MIT BRAKE CONTROL MODUL OPTION: EXT. EMV-FILTER (KL. A) (Sinamics) | Drive Technology | Frequency Converter | SIEMENS |
6SL3310-1GE36-1AA0 | SINAMICS G130 POWER MODULE IP00 3AC 380-480V, 50/60HZ, 605A TYPENLEISTUNG: 315KW (VT) 6-PULSIGE EINSPEISUNG OHNE NETZRUECKSPEISUNG INKL. DRIVE-CLIQ LEITUNG OHNE REGELUNGSBAUGRUPPE | Drive Technology | Frequency Converter | SIEMENS |
6SL3310-1GE37-5AA0 | SINAMICS G130 POWER MODULE IP00 3AC 380-480V, 50/60HZ, 745A TYPENLEISTUNG: 400KW (VT) 6-PULSIGE EINSPEISUNG OHNE NETZRUECKSPEISUNG INKL. DRIVE-CLIQ LEITUNG OHNE REGELUNGSBAUGRUPPE | Drive Technology | Frequency Converter | SIEMENS |
6SL3310-1GE38-4AA0 | SINAMICS G130 POWER MODULE IP00 3AC 380-480V, 50/60HZ, 840A TYPENLEISTUNG: 450KW (VT) 6-PULSIGE EINSPEISUNG OHNE NETZRUECKSPEISUNG INKL. DRIVE-CLIQ LEITUNG OHNE REGELUNGSBAUGRUPPE | Drive Technology | Frequency Converter | SIEMENS |
Repairs Converters – Frequency Converters
In the field of driving automation EICHLER offers a large variety of repair and maintenance for converters and frequency converters. Numerous kinds of make such as Siemens, SEW, Lenze, Danfoss, Bosch, ABB - amongst many others - can be serviced at our works. Especially discontinued types of frequency converters cause a much larger investion in costs towards having to migrate this system compared to an expert repair.
Possible Repairs – Converters – Frequency Converters
- Removal of possible faults within the CU
- Repairs on the Internal Power Supply
- Repairs of faults within the intermediate circuit
- Maintaining the drive-level of amplifiers
- Trouble Shooting on electric recovery systems
- Problems with the interface
- Clearing possible faults within the internal safety controls
- Strategic preventative maintenance
Quality management according to ISO 9001:2015
Certified workflow guarantees a consistently high quality of service when testing and repairing your component.
Nuclear Safety Committee 1401
As one of the first service providers, EICHLER is authorised to repair and sell automation and control technology in the nuclear sector.
Environmental management according to ISO 14001:2015
Standardized procedures for cleaning, repair and, if necessary, the disposal of components ensure a sustainable, environmentally sound use of resources.
Sale on a large variety of new and refurbished frequency converters
EICHLER offers a large variety of current and discontinued types of converters. Every module is fully tested and fitted with a 24 months warranty and enables you to build up or restock your spareparts deposit.
We stock more than 30.000 components
To be able to offer you a large variety of current and discontinued devices EICHLER manages an own stock level of over 30.000 components. This enables us to service you with the necessary module as very short notice – even in case of a breakdown in your system.
Function is fully tested
Every module you purchase at EICHLER is fully tested on all relevant functions before it leaves our works. The combination of highly experienced staff together with our specific Trial- and Testracks give you the necessary safety on the purchase of refurbished automation equipment.
Warranty included
Full trial runs give you the guarantee of the highest possible level on repair service and function of the part sent to us. The item returned to is fitted with a 24 months warranty. If you wish to have an optional test of all parameters we are able to extend this warranty up to 36 months.
Your Direct Line to EICHLER GmbH
Emergency-Hotline - Machine Breakdown
24/7 Spare Parts Service
Service-Hotline - Sales, Maintenance Contracts and Repairs
Technical Trainings - Information & Booking
Life Cycle Management - Information & Appointments
Purchase of Overstockings