Driving and Driving Automation Components
Intelligent Search for Components
Search according to your product code, category of product or manufacturer and you will find your requested component fast and easy. Should you nevertheless not be able to trace the part you are looking for – our experts will gladly help you Tel: +49 8196 9000-110.
Your efficient Partner for the repair and distribution of Driving and Driving Automation Components
For over 40 years now EICHLER stands for the leading Service provider for current and discontinued components for drives and driving automation equipment covering most known manufacturers. The repair On Board will ensure a longer Life Cycle of Industrial Facilities and will reduce costs in view of having to migrate to newer systems. Apart from this EICHLER also can help by offering Sale, Distribution or procurement of used or brand new components. In the field of life cycle management, EICHLER offers sophisticated stock management concepts to ensure the long-term availability of industrial electronics.
Drives and Driving Automation - Our Range of Services
Get to know our range of service in view of repair and distribution on drives and driving automation equipment
- Service on a large variety of different manufacturers
- On Board Repair
- 24 Months Warranty
- Unique Testing Devices
- Emergency Repair
- Your own person of contact
Quality management according to ISO 9001:2015
Certified workflow guarantees a consistently high quality of service when testing and repairing your component.
Nuclear Safety Committee 1401
As one of the first service providers, EICHLER is authorised to repair and sell automation and control technology in the nuclear sector.
Environmental management according to ISO 14001:2015
Standardized procedures for cleaning, repair and, if necessary, the disposal of components ensure a sustainable, environmentally sound use of resources.
Driving and Driving Automation Components
Frequency Converters
Frequency converters are made to actuate and control motors. They are often under heavy use due to the high currents passing through these kind of systems and the constant changes of workloads required. EICHLER exchanges all relevant parts semiconductors and capacitors and offers preventative maintenance.
Rectifiers and Regenerative Units
Rectifiers and regenerative Units will be tested under realistic conditions and under full capacity if requested for.
Modulators
Repairing modulators is part of the daily routine at EICHLER. These units can be repaired or exchanged within very short notice.
Inverters
Inverters play an essential part in the actuation of motors. They are often under heavy use due to the high currents passing through these kind of systems and the constant changes of workloads required. EICHLER exchanges all relevant parts semiconductors and capacitors and offers preventative maintenance.
PLC Devices
PLC devices tell the system to do what it has to do. In nearly every automated unit the PLC devices are the core of the specific installation. These modules require the highest level in competence and know-how of the actual repair needed.
Motors and Accessories
In order to provide you with the possible service in this field, EICHLER works together with highly qualified partners. Your motors are in very good hands and are always serviced according to the high EICHLER standards.
Customer Comments
„…we would like to express our appreciation towards an absolutely top level Customer Service. Having been able to repair our Relanko-Modulator you helped to solve a very severe problem. For this we thank you very much once again. Due to the competence shown you have gained another steady customer. “
ppa. Niels Kollmorgen, AMC Pancke AG
Drives and driving automation - our range of services
In the following you will see a Product Overview showing On-Line available drives and driving automation equipment. For further details to the individual module simply click to the article code. Alternatively refer to our Intelligent Search Mode or simply contact us by telephone: +49 8196 9000-110
Article Name | Article Description | Scope | Article Group Name | Manufacturer |
---|---|---|---|---|
1FN6007-1LC31-0KA1 | SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 315N; FN,TH = 98...239N; FN = 133N; VMAX_FN = 386M/MIN; VMAX_FMAX = 187M/MIN; IN,TH = 1,17... 3,2A; IN = 1,61A;IMAX =5,18A; P_N = 0,911KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. | Drive Technology | Motors and Accessories | SIEMENS |
1FN6007-1LC46-0KA1 | SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 315N; FN,TH = 98...239N; FN = 133N; VMAX_FN = 562M/MIN; VMAX_FMAX = 276M/MIN; IN,TH = 1,69...4,6A; IN = 2,31A;IMAX =7,45A; P_N = 1,3KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. | Drive Technology | Motors and Accessories | SIEMENS |
1FN6007-1LE20-0KA1 | SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 630N; FN,TH = 196...477N; FN = 265N; VMAX_FN = 265M/MIN; VMAX_FMAX = 120M/MIN; IN,TH = 1,69...4,6A; IN = 2,31A;IMAX =7,45A; P_N = 1,29KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. | Drive Technology | Motors and Accessories | SIEMENS |
1FN6007-1LE53-0KA1 | SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 630N; FN,TH = 196...477N; FN = 265N; VMAX_FN = 668M/MIN; VMAX_FMAX = 315M/MIN; IN,TH = 4,11...11,2A; IN = 5,63A;IMAX =18,2A; P_N = 3,08KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. | Drive Technology | Motors and Accessories | SIEMENS |
1FN6007-1LG12-0KA1 | SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 945N; FN,TH = 294...716N; FN = 398N; VMAX_FN = 169M/MIN; VMAX_FMAX = 71,7M/MIN; IN,TH = 1,69...11,2A; IN = 2,31A;IMAX =7,45A; P_N = 1,3KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. | Drive Technology | Motors and Accessories | SIEMENS |
1FN6007-1LG33-0KA1 | SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 945N; FN,TH = 294...716N; FN = 397N; VMAX_FN = 435M/MIN; VMAX_FMAX = 200M/MIN; IN,TH = 4,11...11,2A; IN = 5,63A;IMAX =18,2A; P_N = 3,07KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. | Drive Technology | Motors and Accessories | SIEMENS |
1FN6007-1LJ08-0KA1 | SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1260N; FN,TH = 392...955N; FN = 531N; VMAX_FN = 122M/MIN; VMAX_FMAX = 47,4M/MIN; IN,TH = 1,69...4,6A; IN = 2,31A;IMAX =7,45A; P_N = 1,32KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. | Drive Technology | Motors and Accessories | SIEMENS |
1FN6007-1LJ24-0KA1 | SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1260N; FN,TH = 392 ...955N; FN = 531N; VMAX_FMAX = 320M/MIN; VMAX_FMAX = 143M/MIN; IN,TH = 4,11...11,2A; IN = 5,63A;IMAX =18,2A; P_N = 3,08KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. | Drive Technology | Motors and Accessories | SIEMENS |
1FN6007-1LL05-0KA1 | SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1570N; FN,TH = 490...1190N; FN = 663N; VMAX_FN = 93,9M/MIN; VMAX_FMAX = 32,4M/MIN; IN,TH = 1,69...4,6A; IN = 2,31A;IMAX =7,45A; P_N = 1,33KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. | Drive Technology | Motors and Accessories | SIEMENS |
1FN6007-1LL18-0KA1 | SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1570N; FN,TH = 490...1190N; FN = 663N; VMAX_FN = 251M/MIN; VMAX_FMAX = 110M/MIN; IN,TH = 4,11...11,2A; IN = 5,63A;IMAX =18,2A; P_N = 3,1KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. | Drive Technology | Motors and Accessories | SIEMENS |
1FN6007-1LN15-0KA1 | SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1890N; FN,TH = 588...1430N; FN = 794N; VMAX_FN = 206M/MIN; VMAX_FMAX = 87,9M/MIN; IN,TH = 4,11...11,2A; IN = 5,63A;IMAX =18,2A; P_N = 3,11KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. | Drive Technology | Motors and Accessories | SIEMENS |
1FN6007-1LN32-0KA1 | SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1890N; FN,TH = 588...1430N; FN = 796N; VMAX_FN = 429M/MIN; VMAX_FMAX = 194M/MIN; IN,TH = 8,22...21A; IN = 11,3A;IMAX =36,3A; P_N = 6,08KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. | Drive Technology | Motors and Accessories | SIEMENS |
1FN6007-1SC00-0AA0 | SIMOTICS L SECONDARY SECTION FOR LINEAR MOTOR 1FN6; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COMPENSATING PIECE OF LENGTH; FRAME SIZE 1FN6007; LENGTH 200MM | Drive Technology | Motors and Accessories | SIEMENS |
1FN6007-1SF00-0AA0 | SIMOTICS L SECONDARY SECTION FOR LINEAR MOTOR 1FN6; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; FRAME SIZE 1FN6007; | Drive Technology | Motors and Accessories | SIEMENS |
1FN6007-1WC31-0KA1 | SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; WATER COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 315N;FN = 239N; VMAX_FN = 272M/MIN; VMAX_FMAX = 187M/MIN; IN = 3,2A;IMAX = 5,18A; P_N =1,31KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. | Drive Technology | Motors and Accessories | SIEMENS |
1FN6007-1WC46-0KA1 | SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; WATER COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 315N;FN = 239N; VMAX_FN = 399M/MIN; VMAX_FMAX = 276M/MIN; IN = 4,6A;IMAX = 7,45A; P_N =1,82KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. | Drive Technology | Motors and Accessories | SIEMENS |
1FN6007-1WE20-0KA1 | SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; WATER COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 630N;FN = 477N; VMAX_FN = 180M/MIN; VMAX_FMAX = 120M/MIN; IN = 4,6A;IMAX = 7,45A; P_N =1,9KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. | Drive Technology | Motors and Accessories | SIEMENS |
1FN6007-1WE53-0KA1 | SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; WATER COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 630N;FN = 477N; VMAX_FN = 462M/MIN; VMAX_FMAX = 315M/MIN; IN = 11,2A;IMAX = 18,2A; P_N =4,19KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. | Drive Technology | Motors and Accessories | SIEMENS |
1FN6007-1WG12-0KA1 | SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; WATER COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 945N;FN = 716N; VMAX_FN = 111M/MIN; VMAX_FMAX = 71,7M/MIN; IN = 4,6A;IMAX = 7,45A; P_N =2,03KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. | Drive Technology | Motors and Accessories | SIEMENS |
1FN6007-1WG33-0KA1 | SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; WATER COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 945N;FN = 716N; VMAX_FN = 296M/MIN; VMAX_FMAX = 200M/MIN; IN = 11,2A;IMAX = 18,2A; P_N =4,29KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. | Drive Technology | Motors and Accessories | SIEMENS |
1FN6007-1WJ08-0KA1 | SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; WATER COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1260N;FN = 955N; VMAX_FN = 77,6M/MIN; VMAX_FMAX = 47,4M/MIN; IN = 4,6A;IMAX = 7,45A; P_N =2,17KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. | Drive Technology | Motors and Accessories | SIEMENS |
1FN6007-1WJ24-0KA1 | SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; WATER COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1260N;FN = 955N; VMAX_FN = 215M/MIN; VMAX_FMAX = 143M/MIN; IN = 11,2A;IMAX = 18,2A; P_N =4,43KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. | Drive Technology | Motors and Accessories | SIEMENS |
1FN6007-1WL05-0KA1 | SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; WATER COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1570N;FN = 1190N; VMAX_FN = 57,5M/MIN; VMAX_FMAX = 32,4M/MIN; IN = 4,6A;IMAX = 7,45A; P_N =2,31KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. | Drive Technology | Motors and Accessories | SIEMENS |
1FN6007-1WL18-0KA1 | SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; WATER COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1570N;FN = 1190N; VMAX_FN = 167M/MIN; VMAX_FMAX = 110M/MIN; IN = 11,2A;IMAX = 18,2A; P_N =4,58KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. | Drive Technology | Motors and Accessories | SIEMENS |
1FN6007-1WN15-0KA1 | SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; WATER COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1890N;FN = 1430N; VMAX_FN = 135M/MIN; VMAX_FMAX = 87,9M/MIN; IN = 11,2A;IMAX = 18,2A; P_N =4,74KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. | Drive Technology | Motors and Accessories | SIEMENS |
1FN6007-1WN32-0KA1 | SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; WATER COOLING SYSTEM; 3-PHASE SYNCHRONOUS MOTOR; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1890N;FN = 1430N; VMAX_FN = 288M/MIN; VMAX_FMAX = 194M/MIN; IN = 21A;IMAX = 36,3A; P_N =8,42KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. | Drive Technology | Motors and Accessories | SIEMENS |
1FT6134-6WD76-5AG2 | SIMOTICS S SYNCHRONOUS SERVOMOTOR 1FT6; 200 NM, 100 K, 2500 REV/MIN WATER-COOLED; DESIGN IM B35; FOR TERMINAL BOX CONNECTION AND SIGNAL CONNECTOR TERMINAL BOX CROSSWISE RIGHT; INCREM. ENCODER, SIN/COS 1 VPP 2048 P/REV (ENCODER I-2048); PLAIN SHAFT, ROTATIONAL TOLERANCE N WITHOUT HOLDING BRAKE; VIBRATION SEVERITY GRADE N ROTARY SHAFT SEAL (IP 67); | Drive Technology | Motors and Accessories | SIEMENS |
1FT7086-5WF71-9BL0-ZN1AS0 | SIMOTICS S SYNCHRONMOTOR 1FT7, 36 NM (100K), 4500 U/MIN, 11,80KW FREMDBELUEFTET; BAUFORM IMB 5 (IM V1, IM V3) FLANSCH 1 (1FT6 KOMPATIBEL), FESTER STECKER, ABSOLUTWERTGEBER 24 BIT + 12 BIT MULTITURN MIT DRIVE-CLIQ SCHNITTSTELLE (ENCODER AM24DQI) M. PASSFE | Drive Technology | Motors and Accessories | SIEMENS |
1FT7087-7SH71-1BH0-ZN05N2 | SIMOTICS S SYNCHRONMOTOR 1FT7, 48 NM (100K), 4500 U/MIN, 10,80KW FREMDBELUEFTET; BAUFORM IMB 5 (IM V1, IM V3) FLANSCH 1 (1FT6 KOMPATIBEL), LEISTUNGSSTECKER STECKERABGANGSRICHTUNG QUER RECHTS ABSOLUTWERTGEBER SINGLETURN 24BIT MIT DRIVE-CLIQ SCHNITTSTELLE | Drive Technology | Motors and Accessories | SIEMENS |
1FT7087-7SH71-1BH0-ZN27 | SIMOTICS S SYNCHRONOUS MOTOR 1FT7, 48 NM (100K), 4500 RPM, 10,80KW SEPARATE VENTILATION; FRAME SIZE IMB 5 (IM V1, IM V3) FLANGE 1 (1FT6 COMPATIBLE) POWER CONNECTOR OUTGOING CONNECTOR DIRECTIONTRAVERSE RIGHT ABSOLUTE VALUE ENCODER SINGLETURN 24 BIT WITH DRIVE-CLIQ INTERFACE (ENCODER AS24DQI) PLAIN SHAFT, WITH HOLDING BRAKE; ACCURACY TOLERANCE N VIBRATION SEVERITY GRADE A, DEGREE OF PROTECTION IP 64 N27: BREAKE WITH REDUCED TORQUE OF INERTIA CUSTOMER SPEC. MOTOR SMR-8-2014 | Drive Technology | Motors and Accessories | SIEMENS |
1FT7087-7SH71-4BH0-ZN05N2 | SIMOTICS S SYNCHRONMOTOR 1FT7, 48 NM (100K), 4500 U/MIN, 10,80KW FREMDBELUEFTET; BAUFORM IMB 5 (IM V1, IM V3) FLANSCH 1 (1FT6 KOMPATIBEL), LEISTUNGSSTECKER STECKERABGANGSRICHTUNG AXIAL-DE ABSOLUTWERTGEBER SINGLETURN 24BIT MIT DRIVE-CLIQ SCHNITTSTELLE(EN | Drive Technology | Motors and Accessories | SIEMENS |
1FW3203-3LS62-5AA0 | SIMOTICS T COMPLETE TORQUE MOTOR 1FW3 CUST. SPECIFIC WINDING DESIGN WATER COOLING SYSTEM ENCODER MOUNTING COAXIAL ABSOLUTE ENCODER SINGLETURN 24 BIT (AS24DQI) IMB 14 TERMINAL BOX ON TOP CROSSW. RIGHT WATER CONNECTION LEFT HOLLOW SHAFT BEARING: STANDARD | Drive Technology | Motors and Accessories | SIEMENS |
1FW3204-1BG62-4AS0 | SIMOTICS T COMPLETE TORQUE MOTOR 1FW3 1000MM, 250RPM WATER COOLING SYSTEM SPECIAL WINDING DESIGN ABSOLUTE ENCODER SINGLETURN 24 BIT (AS24DQI) ENCODER MOUNTING COAXIAL IMB 14 TERMINAL BOX CROSSWISE RIGHT WATER CONNECTION LEFT PLUG-ON SHAFT WITH INTEGRATED SHAFT HOLDER DEGREE OF PROTECTION BEARING STANDARD | Drive Technology | Motors and Accessories | SIEMENS |
1FW3208-1UE72-5AA3-ZK24K4 | SIMOTICS T TORQUEMOTOR, 2000NM, 150U/MIN, 26,18KW KUNDENSPEZIFISCHE SONDERAUSFUEHRUNG T20: WELLENABDECKUNG AUF NDE (BEI KOAXIALEN GEBERANBAU NICHT ERFORDERLICH) K24: NUR GRUNDIERUNG RAL 6021 (GRUEN) OHNE FARBE K40: NACHSCHMIEREINRICHTUNG AUF AS UND BS P2 | Drive Technology | Motors and Accessories | SIEMENS |
1FW3285-2AG74-5AY2-ZS32 | SIMOTICS T COMPLETE TORQUE MOTOR 1FW3 270RPM,138,5KW,4900NM,241A,437V WATER COOLING INCL. REGREASING DEVICE (OPTION K40) INCREM. ENCODER SIN/COS 1VPP 2048 S/R WITH C- AND D-TRACK (ENCODER IC2048S/R); ENCODER MOUNTING OVER BELT; IMB 35; TERMINAL BOX ABOVE:CROSSSWISE RIGHT;WATER CONNECTION LEFT EXTRUDER MOTOR MODEL WITH SCREW INTAKE AND INTEGRATED THRUST BEARING S32: MAXIMUM THRUST LOAD IN KN: 200;SCREW DIAMETER IN MM:60 SCREW INTAKE :N 55X3X30;X17X9H DIN5480 USABLE LENGTH 87MM; CYLINDER FLANGE(CENTERED):60 T | Drive Technology | Motors and Accessories | SIEMENS |
1FW4401-1HA.4-1AA0 | HT-DIRECT PERMANENT ERREGTE SYNCHRONMASCH NIEDERSPANNUNGSMOTOR SCHUTZART: IP55 KUEHLART: IC 71W 9375NM; 200 U/MIN 3AC, 50HZ BAUFORM: IM V1 MIT SCHUTZDACH | Drive Technology | Motors and Accessories | SIEMENS |
1FW4401-1HB.4-1AA0 | HT-DIRECT PERMANENT ERREGTE SYNCHRONMASCH NIEDERSPANNUNGSMOTOR SCHUTZART: IP55 KUEHLART: IC 71W 9060NM; 300 U/MIN 3AC, 50HZ BAUFORM: IM V1 MIT SCHUTZDACH | Drive Technology | Motors and Accessories | SIEMENS |
1FW4401-1HC.4-1AA0 | HT-DIRECT PERMANENT ERREGTE SYNCHRONMASCH NIEDERSPANNUNGSMOTOR SCHUTZART: IP55 KUEHLART: IC 71W 8750NM; 400 U/MIN 3AC, 50HZ BAUFORM: IM V1 MIT SCHUTZDACH | Drive Technology | Motors and Accessories | SIEMENS |
1FW4401-1HD.4-1AA0 | HT-DIRECT PERMANENT ERREGTE SYNCHRONMASCH NIEDERSPANNUNGSMOTOR SCHUTZART: IP55 KUEHLART: IC 71W 8440NM; 500 U/MIN 3AC, 50HZ BAUFORM: IM V1 MIT SCHUTZDACH | Drive Technology | Motors and Accessories | SIEMENS |
1FW4401-1HE.4-1AA0 | HT-DIRECT PERMANENT ERREGTE SYNCHRONMASCH NIEDERSPANNUNGSMOTOR SCHUTZART: IP55 KUEHLART: IC 71W 8125NM; 600 U/MIN 3AC, 50HZ BAUFORM: IM V1 MIT SCHUTZDACH | Drive Technology | Motors and Accessories | SIEMENS |
1FW4401-1HF.4-1AA0 | HT-DIRECT PERMANENT ERREGTE SYNCHRONMASCH NIEDERSPANNUNGSMOTOR SCHUTZART: IP55 KUEHLART: IC 71W 7500NM; 800 U/MIN 3AC, 50HZ BAUFORM: IM V1 MIT SCHUTZDACH | Drive Technology | Motors and Accessories | SIEMENS |
1FW4403-1HA.4-1AA0 | HT-DIRECT PERMANENT ERREGTE SYNCHRONMASCH NIEDERSPANNUNGSMOTOR SCHUTZART: IP55 KUEHLART: IC 71W 11250NM; 200 U/MIN 3AC, 50HZ BAUFORM: IM V1 MIT SCHUTZDACH | Drive Technology | Motors and Accessories | SIEMENS |
1FW4403-1HB.4-1AA0 | HT-DIRECT PERMANENT ERREGTE SYNCHRONMASCH NIEDERSPANNUNGSMOTOR SCHUTZART: IP55 KUEHLART: IC 71W 10875NM; 300 U/MIN 3AC, 50HZ BAUFORM: IM V1 MIT SCHUTZDACH | Drive Technology | Motors and Accessories | SIEMENS |
1FW4403-1HC.4-1AA0 | HT-DIRECT PERMANENT ERREGTE SYNCHRONMASCH NIEDERSPANNUNGSMOTOR SCHUTZART: IP55 KUEHLART: IC 71W 10500NM; 400 U/MIN 3AC, 50HZ BAUFORM: IM V1 MIT SCHUTZDACH | Drive Technology | Motors and Accessories | SIEMENS |
1FW4403-1HD.4-1AA0 | HT-DIRECT PERMANENT ERREGTE SYNCHRONMASCH NIEDERSPANNUNGSMOTOR SCHUTZART: IP55 KUEHLART: IC 71W 10125NM; 500 U/MIN 3AC, 50HZ BAUFORM: IM V1 MIT SCHUTZDACH | Drive Technology | Motors and Accessories | SIEMENS |
1FW4403-1HE.4-1AA0 | HT-DIRECT PERMANENT ERREGTE SYNCHRONMASCH NIEDERSPANNUNGSMOTOR SCHUTZART: IP55 KUEHLART: IC 71W 9750NM; 600 U/MIN 3AC, 50HZ BAUFORM: IM V1 MIT SCHUTZDACH | Drive Technology | Motors and Accessories | SIEMENS |
1FW4403-1HF.4-1AA0 | HT-DIRECT PERMANENT ERREGTE SYNCHRONMASCH NIEDERSPANNUNGSMOTOR SCHUTZART: IP55 KUEHLART: IC 71W 9000NM; 800 U/MIN 3AC, 50HZ BAUFORM: IM V1 MIT SCHUTZDACH | Drive Technology | Motors and Accessories | SIEMENS |
1FW4405-1HA.4-1AA0 | HT-DIRECT PERMANENT ERREGTE SYNCHRONMASCH NIEDERSPANNUNGSMOTOR SCHUTZART: IP55 KUEHLART: IC 71W 13125NM; 200 U/MIN 3AC, 50HZ BAUFORM: IM V1 MIT SCHUTZDACH | Drive Technology | Motors and Accessories | SIEMENS |
1FW4405-1HB.4-1AA0 | HT-DIRECT PERMANENT ERREGTE SYNCHRONMASCH NIEDERSPANNUNGSMOTOR SCHUTZART: IP55 KUEHLART: IC 71W 12690NM; 300 U/MIN 3AC, 50HZ BAUFORM: IM V1 MIT SCHUTZDACH | Drive Technology | Motors and Accessories | SIEMENS |
1FW4405-1HC.4-1AA0 | HT-DIRECT PERMANENT ERREGTE SYNCHRONMASCH NIEDERSPANNUNGSMOTOR SCHUTZART: IP55 KUEHLART: IC 71W 12250NM; 400 U/MIN 3AC, 50HZ BAUFORM: IM V1 MIT SCHUTZDACH | Drive Technology | Motors and Accessories | SIEMENS |
We service the repair for a very large scale on different manufacturers of mobile automation equipment
For now over 40 years EICHLER has built up an unique knowledge and experience in repair and distribution of PLC components, HMI operation units and drives and driving automation modules. We service the repair and offer the distribution on a very large scale on different manufacturers of mobile automation equipment such as HMI operating systems, PLC Modules and controlling units together with components on driving automation and motors.
- Large scale on repairs for currently relevant or discontinued components
- On-Board repairs based on specific repairs according to the actual damage
- Unique testing equipment will ensure to detect even very unusual failures
- Realistic trials under full capacity will guarantee you the necessary function.
- 24 months warranty for the repair serviced
Convince yourself on the quality of repair EICHLER offers. Simply download the delivery note, fill out the form and send us the part in question.
Unique Testing Devices for drives and driving automation equipment
Our testing equipment for drives and driving automation equipment such as frequency converters or special transistors is exceptional. Thorough checking of the incoming modules with the help of fully automated Test Stands enable us to detect even very sporadic problems with no apparent cause applying our final tests under realistic conditions under full capacity ensure the function of both repaired and refurbished modules.
- More than 40 years of experience in designing and building testing equipment
- Our testing equipment is built for a large variety of different manufacturers for PLC Boards and Control Units
- The automated testing of certain parameters ensure the actual function.
- 24 months warranty for the repair serviced of the items purchased
No matter if you request a repair for a frequency converter or would like to buy a refurbished module the unique testing devices at EICHLER will guarantee the function required. Convince yourself on the quality of repair EICHLER offers. Simply download the delivery note, fill out the form and send us the part in question.
Your Direct Line to EICHLER GmbH
Emergency-Hotline - Machine Breakdown
24/7 Spare Parts Service
Service-Hotline - Sales, Maintenance Contracts and Repairs
Technical Trainings - Information & Booking
Life Cycle Management - Information & Appointments
Purchase of Overstockings